Models
OVBF: Brass
OVJF: Cast Iron
OVSF: Cast Steel
OVSSF: Stainless Steel
OVJ‐SPF: Cast Iron with Steel Parts
- API 520 & 614 Approved
- Chatter-free operation
- Mount in any position
- Suitable for continuous duty
Size Range: 1″ – 2″
Pressures: 10 – 500 psi
Flow Rate : Up to 150 gpm

The OV-Series valve is a “Relief Valve” (RV) in a sense that the outlet pressure doesn’t affect the valve’s set pressure. The valves operate off the inlet pressures only. The OV-Series valve is to be used when you don’t want the backpressure to affect the valve’s opening pressure.
INSTALLATION, MAINTENANCE & OPERATION
Installation
Fulflo valves can be mounted in any position. A tee may be inserted in the pump discharge line to mount the valve. The correct size of the valve should be installed, preferably matching the pump discharge line. Screw the valve into the nipple in the tee, or in the case of the flange style, bolt the valve to the companion flange screwed into the nipple. When the valve is used for frequent bypassing of oil pressure, its outlet should be piped back to the tank. Care must be taken to have the discharge well below the oil level in the tank to prevent air entrainment and erratic operation.
Read More
Only if the valve is used as safety or overload relief and operates infrequently may its discharge be piped back into the pump suction line. Frequent or continuous operation under these conditions will cause excessive heating of the oil and possible damage.
Setting Valves
Valves may be set with a hydraulic hand pump for cracking pressure. If a test stand is available, the valve should be connected to the discharge header with the pump bypass open, and the bypass gradually closed until the desired pressure registers on the gauge. Adjust valve adjusting screw until valve slightly bleeds at the set bypass pressure and lock adjusting screw.
Fulflo valves are not designed to be positive shut-off and will pass a minimal amount of leakage before the set pressure. If a valve is required to bypass a given amount of fluid at a given pressure, a test stand having a flow meter in the pump discharge line must be available. With a valve adjusted for cracking pressure as above, continue closing the bypass until the required flow registers on the flow meter and observe pressure. Readjust pressure, if necessary, to obtain desired pressure at desired flow.
Maintenance & Operation
Fulflo valves provide reliable “chatter-free” operations when the system is free of abrasives and foreign matter. Continuous filtration of the liquid used is strongly recommended.
TYPICAL APPLICATIONS

TYPICAL DISASSEMBLY OF STANDARD TYPE VALVE
To dismantle valve for inspection or cleaning:
- Remove cap “B”
- Remove lock nut “F”
- Remove adjusting screw “C”
- Remove retainer “D”
- Remove spring “G”
- Remove piston “I”
- Remove stop ring “H” (Not Recommended-Special tooling is required to install new stop ring)
Inspect valve bore and piston for wear and scoring. Replace broken or damaged parts. Clean all parts thoroughly and re-assemble by reversing the above procedure.

ASSEMBLY NUMBER ID CHART
Read More

Examples

Standard Pressure Range Chart

DIMENSIONS & PARTS
Read More
Dimensions in Inches

Cutaway Drawing

Parts List

+ Recommended spare parts
* See Assembly Number Identification Chart, Symbol Number 10
** See Assembly Number Identification Chart, Symbol Number 13
PERFORMANCE DATA
All valve tests 110˚F to 120˚F Oil Viscosity 150 SSU at 100˚F
(Charts good from 30 to 500 SSU)
Read More

Overpressure: The pressure increase or accumulation above the set pressure when the valve is discharging flow.